{"id":590554,"date":"2025-04-17T10:02:09","date_gmt":"2025-04-17T08:02:09","guid":{"rendered":"https:\/\/mybroadband.co.za\/news\/?p=590554"},"modified":"2025-04-17T10:02:16","modified_gmt":"2025-04-17T08:02:16","slug":"south-african-data-centre-industry-evolving","status":"publish","type":"post","link":"https:\/\/mybroadband.co.za\/news\/cloud-hosting\/590554-south-african-data-centre-industry-evolving.html","title":{"rendered":"South African data centre industry evolving"},"content":{"rendered":"\n<p>Teraco CEO Jan Hnizdo says the data centre industry is evolving as players face the need for sustainability, reducing their environmental impact, and meeting the demands of artificial intelligence (AI).<\/p>\n\n\n\n<p>At the same time, they must also manage costs, efficiency, and resilience, ensure connectivity and network performance, and evolve data centre cooling technologies.<\/p>\n\n\n\n<p>&#8220;The data centre industry is ramping up the adoption and development of sustainable practices to limit the industry&#8217;s impact on the environment,&#8221; said Hnizdo.<\/p>\n\n\n\n<p>&#8220;This drive is encouraged by pressure from market regulators, investors, and clients. It is conducive to continuous innovation, epitomised by liquid cooling and using renewable energy to power data centres.&#8221;<\/p>\n\n\n\n<p>As he mentioned, using renewable power sources to power data centre operations is part and parcel of improving sustainability and reducing environmental impact.<\/p>\n\n\n\n<p>Hnizdo says Teraco is dedicated to sustainably and responsibly powering, protecting, connecting, and growing enterprises and ecosystems in Africa.<\/p>\n\n\n\n<p>&#8220;Teraco&#8217;s protect, connect, grow strategy aligns our sustainability initiatives with the material issues impacting our business, clients, and communities,&#8221; he said.<\/p>\n\n\n\n<p>&#8220;Our ambitions align with the seven United Nations Sustainable Development Goals (UN SDGs) that are the most important to our strategy.&#8221;<\/p>\n\n\n\n<p>He added that Teraco will continue to drive its renewable energy goals by:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Maximising rooftop solar coverage across all existing and newly-built facilities.<\/li>\n\n\n\n<li>Investing and engaging utility scale wheeled energy solutions from renewable energy sources.<\/li>\n\n\n\n<li>Evaluating and implementing alternative green energy offset mechanisms for our and our clients&#8217; energy consumption.<\/li>\n<\/ul>\n\n\n\n<p>&#8220;We have committed to powering our data centre colocation facilities with 50% renewable energy by 2027 and 100% by 2035,&#8221; said Hnizdo.<\/p>\n\n\n\n<p>&#8220;We have also maximised our combined rooftop solar footprint across all our facilities, which equated to roughly 80,000MWh in energy savings by the end of 2023.&#8221;<\/p>\n\n\n\n<p>With AI, and by extension, generative AI, poised to continue growing, data centre operators must ensure they can support the technology&#8217;s compute requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">AI puts pressure on data centres<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"563\" src=\"https:\/\/mybroadband.co.za\/news\/wp-content\/uploads\/2024\/11\/Jan-Hnizdo.jpg\" alt=\"\" class=\"wp-image-569573\" srcset=\"https:\/\/mybroadband.co.za\/news\/wp-content\/uploads\/2024\/11\/Jan-Hnizdo.jpg 1000w, https:\/\/mybroadband.co.za\/news\/wp-content\/uploads\/2024\/11\/Jan-Hnizdo-600x338.jpg 600w, https:\/\/mybroadband.co.za\/news\/wp-content\/uploads\/2024\/11\/Jan-Hnizdo-768x432.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Jan Hnizdo, Teraco CEO<\/figcaption><\/figure>\n\n\n\n<p>Citing research from Epoch AI, Hnizdo said AI compute intensity doubles every six to 10 months.<\/p>\n\n\n\n<p>&#8220;While much focus has justifiably been placed on how AI will transform companies, careers, and communications, none of it is possible without the infrastructure built to meet the increasing demand,&#8221; he said.<\/p>\n\n\n\n<p>He added that data centres and edge networks are critical for and enable AI applications.<\/p>\n\n\n\n<p>&#8220;They do so by using high-performance computing (HPC) clusters that require considerable power and, as a result, generate a lot of heat,&#8221; said Hnizdo.<\/p>\n\n\n\n<p>He added that the need for high-density cooling and power is emerging at a record rate.<\/p>\n\n\n\n<p>&#8220;HPC has changed our world virtually overnight, and the world&#8217;s critical digital infrastructure is tasked with keeping place,&#8221; he said.<\/p>\n\n\n\n<p>&#8220;Vertiv is among the companies focused on answering this challenge and leading by example, particularly where technology and sustainability intersect.&#8221;<\/p>\n\n\n\n<p>Hnizdo said the power demands of typical data centre computer racks are expected to increase significantly from 5kW to 7kW today to 50kW or more in the not-too-distant future.<\/p>\n\n\n\n<p>This could result in cooling challenges, highlighting the requirement for enhanced cooling technologies.<\/p>\n\n\n\n<p>&#8220;As supercomputers continue to shrink and become more power-dense, our industry constantly thinks about how we keep them cool while concurrently tapping alternative power sources to support the increased energy demand,&#8221; said Hnizdo.<\/p>\n\n\n\n<p>He said several approaches are emerging:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"box-sizing: border-box; margin: 0px; padding: 0px;\"><strong>Air cooling<\/strong>&nbsp;\u2014 rear-door heat exchangers, in conjunction with air cooling, can displace heat outside the servers.<\/span><\/li>\n\n\n\n<li><strong>Immersion cooling<\/strong> \u2014 submerging servers and other components in a thermally conductive dielectric liquid or fluid.<\/li>\n\n\n\n<li><strong>Direct-to-chip liquid co<\/strong><b>o<\/b><strong>ling <\/strong>\u2014 delivers cooling liquid through cold plates laying atop the heat sources within the computers, drawing heat away when the liquid circulates.<\/li>\n<\/ul>\n\n\n\n<p>However, a combination of these approaches may be required.<\/p>\n\n\n\n<p>&#8220;Moving forward, data centres will need to tightly orchestrate liquid and air cooling (a hybrid strategy) to optimise the overall environment within the facility,&#8221; said Hnizdo. <\/p>\n\n\n\n<p>&#8220;The data centre industry must continue to evolve to provide the cooling and power solutions needed to support evolving data centre challenges and maximise AI&#8217;s true potential.&#8221;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Teraco CEO Jan Hnizdo highlights some of the biggest challenges data centre operators in South Africa face.<\/p>\n","protected":false},"author":341076,"featured_media":533023,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[25],"tags":[35793,94467,22807,37525,29400,1573,441],"class_list":["post-590554","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cloud-hosting","tag-artificial-intelligence-ai","tag-artificial-intelligence-data-centres","tag-data-centres","tag-high-performance-computing","tag-jan-hnizdo","tag-renewable-energy","tag-teraco"],"_links":{"self":[{"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/posts\/590554"}],"collection":[{"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/users\/341076"}],"replies":[{"embeddable":true,"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/comments?post=590554"}],"version-history":[{"count":5,"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/posts\/590554\/revisions"}],"predecessor-version":[{"id":590878,"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/posts\/590554\/revisions\/590878"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/media\/533023"}],"wp:attachment":[{"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/media?parent=590554"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/categories?post=590554"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mybroadband.co.za\/news\/wp-json\/wp\/v2\/tags?post=590554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}